Laserfiche WebLink
Well/Water System Construction Permit <br />Page I Of <br />Loudoun County, Virginia Health Department <br />Division of Environmental Health Identification Number 0117 FW 93 <br />777 -0234 Metro 478 -8408 © ®Q ©0®®®0® <br />Map Reference <br />General Information <br />New ® Repair ❑ Abandonment ❑ Upgrade ❑ Well ID.# <br />Based on the application for a well /water supply system construction permit filed in accordance with Chapter 1040, Codified <br />Ordinances a construction permit is hereby issued to: <br />timothy <br />Owner Snook Telephone 703= 444 -2933 (o) 800 -945 -39.07 <br />Address axa 1 Court, Sterling, VA 20165 <br />IFor a well /water system which is to be constructed on /at R 7 F thru S-t @rl i ng L en Het 17 —Knel l <br />, <br />(A1 onkian Pkw R on Grandgipw P1- 1st Pntra.nc@ on I <br />Subdivision ` ection /Block 82 Lot 2 -A <br />DESIGN <br />NOTE: INSPECTION RESULTS <br />Water supply, existing: (describe) <br />Water supply location: Satisfactory yes 3"' no ❑ <br />Drillers Report (G.W.2) Received yes 13r no ❑ <br />To be installed: class_ <br />Cased and Grouted to Bedrock plus0' or a minimum <br />Well Construction Approval yes [Y no ❑ <br />L- <br />cased M 1r 5 Grouted 6 65 whichever is greater <br />Sanitarian Date 1-:D1 <br />Well Location See Page <br />Well Driller 14 &V Lc tf <br />Pump Installer Lic # <br />I. If well yield as determined by 30 minute airlift test is less <br />Chemical Quality Data Received yes ❑ no ❑ N/A ❑ <br />than 5 gallons per minute, a pumping test must be performed <br />Pumping Data Received yes ❑ no ❑ N/A ❑ <br />as follows: <br />As built sketch on page <br />A. Pump and related equipment shall be installed and <br />Bacterialogical Sample Received yes ❑ no ❑ <br />the static water level measured. <br />Water System Approved yes ❑ no ❑ <br />B. Pumping shall begin at a rate of withdrawal greater <br />Sanitarian Date <br />II. Criteria for approval of well and well yield are as <br />than 5 GPM until water level drops to a point close <br />to bottom of the well. <br />follows: <br />C. At this point, the pump rate shall be adjusted so <br />The well must produce a: <br />the water level remains constant. <br />A. Minimum of 1 gallon per minute for 6 continuous <br />D. Measure and record the volume of water discharge <br />and water level (electric tape) at 15 minute intervals <br />pumping hours after the well has been pumped <br />throughout the test. <br />out according to Part I, Sec. B of this permit. <br />E. Discharge water at least 50 feet from the well and <br />B. The pump test can be terminated early and well <br />sewage disposal area. <br />yield considered adequate if <br />F. Interruption of pumping longer than 15 minutes <br />1. The well cannot be pumped out as stated in <br />shall require extending the pumping time that <br />Part I B of this permit. <br />amount of time. <br />2. The Well yields 2.5 gpm or greater for 3 hours <br />of continuous pumping after Part I B of this <br />permit is completed. <br />The well/water ,s� t is to be constructed as specified <br />C. Sufficient storage and yield may be considered for <br />by the permit f3 or attached plans and specifications ❑. <br />approval. <br />D. Person conducting the pump test shall collect a <br />This water system construction permit is null and void if <br />sample to be analyzed for Constituents described <br />(a) conditions are changed from those shown on the <br />in Codified Ordinances of Loudoun County Title <br />application (b) conditions are changed from those shown <br />4, Chapter 1040, Appendix III. <br />on the construction permit. <br />E. Replacement wells are exempt from this <br />requirement. <br />Date* LfI719 3 Issued by: AW1.14 1 - <br />This Construction <br />Wan <br />Permit Va id yntil <br />Dater Reviewed by: <br />7y <br />pervisory sanitarian <br />Original / Health Departbent Copy / Applicants Copy <br />r� <br />70 <br />G,-o i <br />� ), 4111- <br />'tvQ4. <br />